Nova-tech Pulsatron Plus Series ET Manual de usuario

Busca en linea o descarga Manual de usuario para Zapatillas Nova-tech Pulsatron Plus Series ET. Nova-Tech Pulsatron Plus Series ET User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 17
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Electronic Metering Pumps
Series C, C+, A+, E, E-DC and E+
Installation
Operation
Maintenance
Instruction
READ ALL WARNINGS CAREFULLY
BEFORE INSTALLING
PULSAtron PLUS Series ET Addendum on page 17
Vista de pagina 0
1 2 3 4 5 6 ... 16 17

Indice de contenidos

Pagina 1 - Electronic Metering Pumps

Electronic Metering PumpsSeries C, C+, A+, E, E-DC and E+ InstallationOperationMaintenanceInstructionREAD ALL WARNINGS CAREFULLY BEFORE INSTALLINGPULS

Pagina 2 - TABLE OF CONTENTS

105.5.2 External Pacing Function (E+, A+, C+ and C only) The pump's stroke rate can be controlled by an external signal input. When the input si

Pagina 3 - 1.0 SAFETY INSTRUCTIONS

11The signal cord polarity is: Black = Common White = Positive Wrong polarity can result in excess flow. Signal input impedance is 124 ohms. Remov

Pagina 4 - 2.0 UNPACKING THE PUMP

12Apply grease to areas of the diaphragm that contact the deflection plate. Slide the diaphragm deflection plate onto the back of the diaphragm stud,

Pagina 5 - 4.0 INSTALLATION

137.0 TROUBLESHOOTING Problem Probable Cause Remedy Failure to Pump1. Leak in suction side of pump 2. Valve seats not sealing 3. Low setting on pump

Pagina 6 - 4.2 Piping

14Leakage at Fitting 1. Loose fittings 2. Broken or twisted gasket 3. Chemical attack 1. Tighten hand tight. Replace gasket if hand tightening does

Pagina 8 - 5.0 START UP AND OPERATION

168.0 POLICIES AND PROCEDURES8.1 Manufacturers Product WarrantyThe manufacturer warrants its equipment of its manufacture to be free of defects in mat

Pagina 9 - 5.4 Control Panel Symbols

MANUAL ADDENDUM PULSAtron SERIES ET The PULSAtron Series ‘ET’ pump is slightly different then the ‘E+’ pumps with an external pace option. An exte

Pagina 10

2TABLE OF CONTENTS1.0 SAFETY INSTRUCTIONS ...

Pagina 11 - 6.0 MAINTENANCE

31.0 SAFETY INSTRUCTIONS When using chemical feed pumps, basic safety precautions should always be followed to reduce risk of fire, electric shock, an

Pagina 12 - 6.4 Valve Replacement

4An air bleed valve is available for most models with tubing connections. Air purges should be performed when the pump-chamber contains no fluid at t

Pagina 13 - 7.0 TROUBLESHOOTING

53.0 INTRODUCTIONThese installation, operation and maintenance instructions cover your electronic metering pump. Refer to the pump data label to dete

Pagina 14

6USE AN ANTI-SIPHON VALVE IN THE DISCHARGE LINE whenever the fluid pressure in the discharge line is below atmospheric pressure. This can occur if th

Pagina 15 - Appendix A

7A flooded suction (tank liquid level always at a higher elevation than the pump) is recommended when pumping solutions such as sodium hypochlorite (N

Pagina 16 - 8.0 POLICIES AND PROCEDURES

85.0 START UP AND OPERATION5.1 PowerAll metering pumps are available in 115 and 230 volts at 50/60 Hertz, single phase. In addition, certain models a

Pagina 17

95.3.2 Stroke Length AdjustmentStroke length can be controlled within 0 to 100% of the diaphragm displacement. It should be controlled within 20 to 10

Comentarios a estos manuales

Sin comentarios